Uploaded image for project: 'CDA Specification Feedback'
  1. CDA Specification Feedback
  2. CDA-1354

STU-1354 - Use of Filler order

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: Medium Medium
    • Public Health Case Report - Electronic Initial Case Report (eICR) (CDA)
    • 1.1.1
    • Public Health
    • Narrative Guidance
    • Filler Order
    • Hide

      Persuasive with Modification made 2019-03-07 00:00:00.0 with vote Laura Conn/Sarah Gaunt: 15-0-0//(Impact: Compatible, substantive; Category: Correction; Version: null)//Filler order number is mapped to the organizer/id as the commenter suggests (see mapping table in Volume 1). Will update the note in Volume 2 to specifically point to the correct data element. The DICOM filler order number is different and not related. Mover: Laura Conn Second: Sarah Gaunt Vote: 15-0-0 03/07/2019

      Show
      Persuasive with Modification made 2019-03-07 00:00:00.0 with vote Laura Conn/Sarah Gaunt: 15-0-0//(Impact: Compatible, substantive; Category: Correction; Version: null)//Filler order number is mapped to the organizer/id as the commenter suggests (see mapping table in Volume 1). Will update the note in Volume 2 to specifically point to the correct data element. The DICOM filler order number is different and not related. Mover: Laura Conn Second: Sarah Gaunt Vote: 15-0-0 03/07/2019
    • Laura Conn/Sarah Gaunt : 15-0-0
    • Clarification
    • Compatible, substantive

    Description

      Specification - Extended

      HL7 CDA® R2 Implementation Guide: Public Health Case Report, Release 2: the Electronic Initial Case Report (eICR), Release 1, STU Release 1.1 - US Realm

      Document Description

      extended per TSC Tracker 12574, extension TSC GF 15952, JIRA TSC-29, TSC-123

      Existing Wording

      Use of Filler Order Number in eICR conflicts with term in C-CDA V2.1. There does not seem to be a provision for this data element in Results section. Rather it could map to results organizer. eICR IG 1.1 Page 73 Results Section (Entries Required) (V3) Filler Order Number (Note: If available, the placing system order identifier (Placer Order number) as well ) Conflicts with C-CCDA V2.1 C-CDA V2.1 Page 130 Section 1.1.8.3 inFullfillmentOf (specific to 1.1.7 Diagnostic Imaging Report (V3)) Filler Order Number is mentioned once - The Filler Order number maps directly to the DICOM Accession Number in the DICOM imaging and report data. A widely deployed alternative approach maps the requested procedure identifiers directly to the DICOM Accession Number.