Specification - Extended HL7 CDA® R2 Implementation Guide: Public Health Case Report, Release 2: the Electronic Initial Case Report (eICR), Release 1, STU Release 1.1 - US Realm
Document Description extended per TSC Tracker 12574, extension TSC GF 15952, JIRA TSC-29, TSC-123
Existing WordingUse of Filler Order Number in eICR conflicts with term in C-CDA V2.1. There does not seem to be a provision for this data element in Results section. Rather it could map to results organizer. eICR IG 1.1 Page 73 Results Section (Entries Required) (V3) Filler Order Number (Note: If available, the placing system order identifier (Placer Order number) as well ) Conflicts with C-CCDA V2.1 C-CDA V2.1 Page 130 Section 1.1.8.3 inFullfillmentOf (specific to 1.1.7 Diagnostic Imaging Report (V3)) Filler Order Number is mentioned once - The Filler Order number maps directly to the DICOM Accession Number in the DICOM imaging and report data. A widely deployed alternative approach maps the requested procedure identifiers directly to the DICOM Accession Number.