Uploaded image for project: 'CDA Specification Feedback'
  1. CDA Specification Feedback
  2. CDA-1059

STU-1059 - Result Observation

    XMLWordPrintableJSON

Details

    • Icon: Technical Correction Technical Correction
    • Resolution: Persuasive
    • Icon: Highest Highest

    Description

      Specification - Extended

      HL7 CDA® R2 IG: C-CDA Templates for Clinical Notes DSTU Release 2.1 - US Realm

      Document Description

      extended per extended per TSC tracker 12437, again with 14128 and jira.hl7.org/browse/TSC-38

      Existing Wording

      Result Observation (V3) (urn:hl7ii:2.16.840.1.113883.10.20.22.4.2:2015-08-01) has the following constraint: SHALL contain exactly one [1..1] code, which SHOULD be selected from CodeSystem LOINC (urn:oid:2.16.840.1.113883.6.1) (CONF:1198-7133) Which has the following (tool generated) Schematron: SHALL contain exactly one [1..1] code, which SHOULD be selected from CodeSystem LOINC (urn:oid:2.16.840.1.113883.6.1) (CONF:1198-7133). This Schematron errors if the codeSystem isn't LOINC, which is not correct.

      Proposed Wording

      The (tool generated) Schematron should be: SHALL contain exactly one [1..1] code, which SHOULD be selected from CodeSystem LOINC (urn:oid:2.16.840.1.113883.6.1) (CONF:1198-7133). This is a tooling issue, will also raise a Trifolia bug.

      Attachments

        Activity

          People

            Unassigned Unassigned
            minigrrl Sarah Gaunt
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: