Uploaded image for project: 'CDA Specification Feedback'
  1. CDA Specification Feedback
  2. CDA-1005

STU-1005 - Goal observation

    XMLWordPrintableJSON

Details

    • Icon: Technical Correction Technical Correction
    • Resolution: Persuasive
    • Icon: Medium Medium

    Description

      Specification - Extended

      HL7 CDA® R2 IG: C-CDA Templates for Clinical Notes DSTU Release 2.1 - US Realm

      Document Description

      extended per extended per TSC tracker 12437, again with 14128 and jira.hl7.org/browse/TSC-38

      Existing Wording

      Goal Observation: 5. SHALL contain exactly one [1..1] code, which SHOULD be selected from CodeSystem LOINC (urn:oid:2.16.840.1.113883.6.1) (CONF:1098-30784). ...

      Proposed Wording

      The schematron throws an error when a code element is present with any @codeSystem besides LOINC. It should throw a warning in that case, and an error only if the code element is completely missing. This is not a custom schematron, so it can (and should) be fixed in Trifolia's model before other IG's make use of the Goal Observation.