Details
-
Change Request
-
Resolution: Persuasive
-
Highest
-
US Core (FHIR)
-
6.0.0-ballot [deprecated]
-
Cross-Group Projects
-
STU
-
US Core Blood Pressure Profile
-
-
Eric Haas/Brett Marquard: 13-0-1
-
Correction
-
Compatible, substantive
Description
Profile specific implementation guidance has
- An Observation.component without a value, SHALL include a reason why the data is absent.
- Systems that never provide a component observation without a component value are not required to support Observation.component.dataAbsentReason.
- Because the blood pressure values are communicated in the mandatory systolic and diastolic components:
- all server systems - including those that never provide a component observation without a value - SHALL support Observation.component.dataAbsentReason for the components.
These two guidances are conflict with each other.