Details
-
Change Request
-
Resolution: Persuasive
-
Medium
-
US QI Core (FHIR)
-
4.1.0 [deprecated]
-
Clinical Quality Information
-
QICore AdverseEvent
QICore FamilyMemberHistory
QICoreCondition [deprecated] -
-
Linda Michaelsen/Floyd Eisenberg: 17-0-0 approved
-
Correction
-
Non-compatible
Description
The following elements, sorted by QI-Core profile, are listed as Must Support but have example values set bindings. Change the bindings for these listed elements for Preferred as noted below:
- QICoreAllergyIntolerance
- AllergyIntolerance.reaction.manifestation uses http://hl7.org/fhir/ValueSet/clinical-findings - Change to "Preferred" which allows consistency with CMS Blueprint which adds ICD-10
- QICoreAdverseEvent
- AdverseEvent.event uses http://hl7.org/fhir/ValueSet/adverse-event-type containing All SNOMED Clinical findings - Change to "Preferred"
- QICoreCondition
- Condition.stage.summary uses http://hl7.org/fhir/ValueSet/condition-stage – Change to “Preferred”
- Condition.bodySite uses http://hl7.org/fhir/ValueSet/body-site Change to "Preferred" Consider note to OO to consider update to more recent version of SNOMED
- QICoreFamilyMemberHistory
- FamilyMemberHistory.condition.code uses http://hl7.org/fhir/ValueSet/condition-code - Includes all SNOMED Clinical findings including no current problems or disability. Change to "Preferred"
- QICoreProcedure
- Procedure.reasonCode uses http://hl7.org/fhir/ValueSet/procedure-reason which is basically SNOMED condition codes - Change to "Preferred"
- Procedure.bodySite uses http://hl7.org/fhir/ValueSet/body-site Change to "Preferred" Consider note to OO to consider update to more recent version of SNOMED
- QICoreProcedureNotDone
- Procedure.code uses http://hl7.org/fhir/ValueSet/procedure-code which is basically SNOMED procedure codes - Change to "Preferred"
Attachments
Issue Links
- is duplicated by
-
FHIR-34327 Must Support codeableConcept/coding elements should have at least a preferred binding
- Duplicate
-
FHIR-34365 AdverseEvent.event is a required element but it is bound to an example valueSet
- Duplicate
- relates to
-
FHIR-33230 FamilyMemberHistory profile needs to have a more constrained binding on Relationship code set