Wrong SNOMED code for vomiting in value set allergy reaction (code from wrong semantic hierarchy)

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • International Patient Summary (FHIR)
    • current
    • Patient Care
    • Allergy Intolerance (IPS)

    Description

      http://hl7.org/fhir/uv/ips/ValueSet-allergy-reaction-gps-uv-ips.html :

      The code “

      1985008 Vomitus (substance)

      Is not describing a reaction to an allergy but a substance. Correct is the code:

      422400008 | Vomiting (disorder) |

      Which describes the disorder / finding as do the other codes from this value set. Thank you for changing this entry; we will work with the correct code in our CH-AllergyIntolerance IG, see http://fhir.ch/ig/ch-allergyintolerance/index.html

       