Details
-
Change Request
-
Resolution: Persuasive with Modification
-
Medium
-
US QI Core (FHIR)
-
2.0 [deprecated]
-
Clinical Quality Information
-
QICore MedicationRequest
QICore ServiceRequest -
-
Floyd Eisenberg/ Ben Hamlin: 26-0-2
-
Enhancement
-
Non-compatible
-
Yes
Description
The .intent element of ServiceRequest, MedicationRequest, and NutritionOrder is used to differentiate a clinician recommendation (intent=plan), and order (intent=order) and a Clinical Decision Support recommendation (intent=proposal). To support such differentiation in measures requires that .intent is must support for these profiles. NutritionOrder should also have a Must Support for the .status element to indicate the appropriate status for a measure.
Since we differentiate between order and recommended using the intent element, all of the order-related profiles should have a Must Support for intent.
Specifically recommend:
ServiceRequest.intent add Must Support
MedicationRequest.intent add Must Support
NutritionOrder add Must Support for the .status or the .intent elements