      Agree. Issued is not specified differently and should not be in the differential table.

      • Remove status, code, effective, issued from differential table.
      • Mark performer as MUST SUPPORT.
      • Add result scoped to QI-Core LaboratoryResult
      Show
      Agree. Issued is not specified differently and should not be in the differential table. Remove status, code, effective, issued from differential table. Mark performer as MUST SUPPORT. Add result scoped to QI-Core LaboratoryResult
    • Bryn Rhodes/Ben Hamlin: 13-0-0
    • Correction
    • Non-substantive

    Description

      QI Core DiagnosticReportLab is built on US Core Diagnostic Report Lab (http://hl7.org/fhir/us/core/STU3.1/StructureDefinition-us-core-diagnosticreport-lab.html)

      In that profile, issued and performer are listed as Must Support.  However the QI Core DiagnosticReportLab does not show these values as Must Support.  

      They do show in Differential View

       

      Note QI Core DiagnosticReportNotes has the same issue