Details
-
Change Request
-
Resolution: Persuasive
-
Medium
-
SMART on FHIR (FHIR)
-
1.1.0 [deprecated]
-
FHIR Infrastructure
-
Overview
-
1.0.5.1, 1.0.5.2
-
-
Gino Canessa/Yunwei Wang: 13-0-0
-
Clarification
-
Non-substantive
Description
https://hl7.org/fhir/smart-app-launch/2021May/index.html#ehr-launch-sequence
Section 1.0.5.1 describes the EHR launch sequence and specifies that the app can call either the "/metadata" or ".well-known/smart-configuration" endpoints to receive the OAuth URLs. However, the diagram only shows a call to the "/metadata" endpoint.
Section 1.0.5.2 describes the Standalone App launch sequence. This diagram also only shows a call to the "/metadata" endpoint, though the prose section only specifies using ".well-known/smart-configuration".
The diagrams and prose should be modified to be consistent with each other.
Attachments
Issue Links
- is voted on by
-
BALLOT-17251 Affirmative - Scott Fradkin : 2021-May-HL7 FHIR IG SMART APP LAUNCH R2 STU
- Closed