Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-29144

Differential Table does not include any attributes

    XMLWordPrintableJSON

    Details

    • Type: Change Request
    • Status: Resolved - change required (View Workflow)
    • Priority: Highest
    • Resolution: Persuasive with Modification
    • Specification:
      US Post Acute Orders (FHIR)
    • Raised in Version:
      0.3.0
    • Work Group:
      Orders & Observations
    • Related Page(s):
      (NA)
    • Related Section(s):
      10.4.1
    • Grouping:
    • Resolution Description:
      Hide

      Yes it was intentional for the ballot but will include specific constraints for the final version.

      Show
      Yes it was intentional for the ballot but will include specific constraints for the final version.
    • Resolution Vote:
      Bob Dieterle / Marti Velezis : 4-0-8
    • Change Category:
      Enhancement
    • Change Impact:
      Compatible, substantive
    • Applied for Version:
      0.2.0

      Description

      Differential Table does not include any attributes - is that intentional?

        Attachments

          Issue Links

            Activity

              People

              Assignee:
              Unassigned Unassigned
              Reporter:
              mrocca Mitra Rocca
              Watchers:
              3 Start watching this issue

                Dates

                Created:
                Updated:
                Resolved:
                Vote Date: