Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-28096

Change specimen in ObservationDefinition from 0..1 to 0..*

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • FHIR Core (FHIR)
    • R5
    • Orders & Observations
    • ObservationDefinition
    • Hide

      Set cardinality of specimen to 0..*, as proposed.

      Show
      Set cardinality of specimen to 0..*, as proposed.
    • Francois Macary / Rob Hausam: 13-0-4
    • Correction
    • Compatible, substantive
    • R5

    Description

      Need to add a specimen requirement in ObservationDefinition to aid in LOINC assignment via LIVD 

      Change cardinality from 0..1 to 0..*

      ObservationDefinition.specimen    0..*    Reference(SpecimenDefinition)

      multiple instances of specimen means AND: the observations of this kind need all the kinds of specimens listed.

      Attachments

        Activity

          People

            Unassigned Unassigned
            jdlnolen John D.L. Nolen
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: