Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-27911

Change binding to UCUM from required to extensible + max binding UCUM

    XMLWordPrintableJSON

Details

    • Icon: Technical Correction Technical Correction
    • Resolution: Persuasive
    • Icon: Highest Highest
    • FHIR Core (FHIR)
    • R5
    • Orders & Observations
    • Observation
    • Hide

      for both value[x] and component.value[x]:

      Add and/or change enumerated list of UCUM codes binding to extensible add note it SHOULD be a UCUM code.

      CONSIDER FOR FUTURE

      • Create a slice for quantity type (open, by type)
      • technically change discriminator to patterns from fixed value - 
      Show
      for both value [x] and component.value [x] : Add and/or change enumerated list of UCUM codes binding to extensible add note it SHOULD be a UCUM code. CONSIDER FOR FUTURE Create a slice for quantity type (open, by type) technically change discriminator to patterns from fixed value - 
    • Correction
    • R5

    Description

      Change the binding for UCUM common vitals from required to extensible + max binding UCUM.

      since other profile derived from this profile such as the US Core Pulse Oximetry Profile will require other units.

      Attachments

        Activity

          People

            Unassigned Unassigned
            ehaas Eric Haas
            Watchers:
            4 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: