Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-26647

MeasureReport strata should support components with non-coded values

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • FHIR Core (FHIR)
    • R5
    • Clinical Quality Information
    • MeasureReport
    • Hide

      Agreed, expand component to support CodeableConcept, boolean, Quantity, Range, and Reference as suggested.

      Show
      Agreed, expand component to support CodeableConcept, boolean, Quantity, Range, and Reference as suggested.
    • Floyd Eisenberg/Bryn Rhodes: 28-0-1
    • Enhancement
    • Compatible, substantive
    • R5

    Description

      We're looking at generating some sample data using MeasureReport, and slightly surprised that MeasureReport.group.stratifier.stratum.component (!!) only supports coded values:

      One of our components really should have a Reference-typed value (i.e., for a facet that tells you which Location (specific hospital ward) this stratum is being generated for).

      Overall, it'd be good to make the component value types match http://build.fhir.org/group-definitions.html#Group.characteristic.value_x_ :

      • CodeableConcept
      • boolean
      • Quantity
      • Range
      • Reference

      Attachments

        Activity

          People

            Unassigned Unassigned
            jmandel Josh Mandel
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: