Measure report profiles should require id element

    XMLWordPrintableJSON

    Details

    • Type: Change Request
    • Status: Applied (View Workflow)
    • Priority: Medium
    • Resolution: Persuasive
    • Specification:
      US Da Vinci DEQM (FHIR)
    • Work Group:
      Clinical Quality Information
    • Related Page(s):
      Profiles and Extensions
    • Grouping:
    • Resolution Description:
      Hide

      Will add reference to Measure.population.group.id in MeasureReport.population.group
      to address this issue.

      Will confer with implementers on the exact structure and detailed guidance to give

      Show
      Will add reference to Measure.population.group.id in MeasureReport.population.group to address this issue. Will confer with implementers on the exact structure and detailed guidance to give
    • Resolution Vote:
      Linda Michaelson/Bryn Rhodes: 20-0-0
    • Change Category:
      Enhancement
    • Change Impact:
      Compatible, substantive

      Description

      The MeasureReport profiles should specify that the "id" element is required, since it is needed to relate to the corresponding elements in the Measure (code is insufficient since some measure types have multiple populations with the same code).