Binding on Diagnosis example should be to ICD10-CM instead of ICD-10

    XMLWordPrintableJSON

    Details

    • Type: Change Request
    • Status: Resolved - change required (View Workflow)
    • Priority: Medium
    • Resolution: Persuasive
    • Specification:
      US CARIN Blue Button (FHIR)
    • Raised in Version:
      0.1
    • Work Group:
      Financial Mgmt
    • Related Page(s):
      (NA)
    • Resolution Description:
      Hide

      Change  binding to icd-10-cm (required). The icd-10-cm code system needed will include both active and deprecated codes so that all codes appear as valid for the time frame of the EOBs such as icd-10-cm-all <- example.

      Show
      Change  binding to icd-10-cm (required). The icd-10-cm code system needed will include both active and deprecated codes so that all codes appear as valid for the time frame of the EOBs such as icd-10-cm-all <- example.
    • Resolution Vote:
      Mark Roberts/Pat Taylor: 18-0-5
    • Change Category:
      Enhancement
    • Change Impact:
      Compatible, substantive

      Description

      We know many people take bindings even "example" as the "right one".  I understand this is an example but would be better to bind to  ICD10CM since this is a US IG