Uploaded image for project: 'FHIR Specification Feedback'
  1. FHIR Specification Feedback
  2. FHIR-24436

LIVD IG - LIVD catalog claims unduly to be based on the Catalog profile

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Not Persuasive
    • Icon: Medium Medium
    • US LOINC – IVD Test Code (LIVD) (FHIR)
    • STU3
    • Orders & Observations
    • (profiles) [deprecated]
    • Hide

      Motion to find not persuasive as FMG did not approve the resource. We will investigate as well that we can switch to using the Catalog Profile as the basis rather than Composition directly. 

      Show
      Motion to find not persuasive as FMG did not approve the resource. We will investigate as well that we can switch to using the Catalog Profile as the basis rather than Composition directly. 
    • Rob Hausam / Riki Merrick: 11-0-0

    Description

      Section 1.1.5.1 states that The LIVD catalog profile is based on the Catalog profile based on the Composition resource. In fact this is not the case: Section 2.3.1.1[http://hl7.org/fhir/uv/livd/2019SEP/catalog-uv-livd.html#profile] which specifies the LIVD catalog profile build it directly upon the Composition resource.

      Building the LIVD catalog profile on top of the existing Catalog profile seems as a good idea since LIVD is a kind of catalog. This brings a constraint on the content of Composition.section.entry, which is [1..*] and of the mandatory datatype Reference(CatalogEntry).

      This is a major change to consider on LIVD IG

      Attachments

        Activity

          People

            rhausam Robert Hausam
            fmacary Francois Macary
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: