Specification - Extended HL7 CDA® R2 Implementation Guide: Quality Reporting Document Architecture I (QRDA I) Release 1, STU Release 5.2 - US Realm
Document Description extended per TSC approval Jira TSC-68, errata by CTO
Existing WordingSeveral of the templates that have an act wrapper are not consistently specified to indicate whether to use the id in the contained template or the id in the act wrapper when ensuring data uniqueness. Remove the id conformance statements from the act wrapper and update examples. The id in the contained template in these cases will be used for ensuring data uniqueness.
Proposed WordingEncounter Recommended Act (V3) Remove: 5. MAY contain zero or more [0..*] id (CONF:4444-29659). Remove from example Encounter Order Act (V3) Remove: 5. MAY contain zero or more [0..*] id (CONF:4444-29641). Remove from example Encounter Performed Act (V3) (no changes needed) Device Order Act (V3): remove id from example Device Recommended Act (V3) MAY contain zero or more [0..*] id (CONF:4444-29631). Medication Dispensed Act (V4) Remove 5. SHALL contain at least one [1..*] id (CONF:4444-28564). Remove from example Discharge Medication (V5) Remove 1. SHALL contain at least one [1..*] id (CONF:4444-26955). Remove from example