Uploaded image for project: 'CDA Specification Feedback'
  1. CDA Specification Feedback
  2. CDA-1932

STU-1932 - documentationOf

    XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive with Modification
    • Icon: Medium Medium
    • Public Health Case Report - Electronic Initial Case Report (eICR) (CDA)
    • 1.1.1
    • Public Health
    • Templates
    • Hide

      Persuasive with Modification made 2020-09-23 00:00:00.0 with vote Sarah Gaunt/Craig Newman: 21-0-0//(Impact: Non-substantive; Category: Clarification; Version: null)// Reconciled 9/23/2020 Motion/Second: Sarah/Craig Vote: 21/0/0 It is not correct that you can ?specify a code for automated or can specify a code for manual?. You can ONLY specify that this is an Manually Initiated eICR. When there is no code and documentationOf is not present, this indicates that this is an Automatically Initiated eICR. Will add guidance to clarify this. We will add explanation that states that if there is no code present then this is an automatically initiated eICR.

      Show
      Persuasive with Modification made 2020-09-23 00:00:00.0 with vote Sarah Gaunt/Craig Newman: 21-0-0//(Impact: Non-substantive; Category: Clarification; Version: null)// Reconciled 9/23/2020 Motion/Second: Sarah/Craig Vote: 21/0/0 It is not correct that you can ?specify a code for automated or can specify a code for manual?. You can ONLY specify that this is an Manually Initiated eICR. When there is no code and documentationOf is not present, this indicates that this is an Automatically Initiated eICR. Will add guidance to clarify this. We will add explanation that states that if there is no code present then this is an automatically initiated eICR.
    • Sarah Gaunt / Craig Newman : 21-0-0
    • Clarification
    • Non-substantive

    Description

      Specification - Extended

      HL7 CDA® R2 Implementation Guide: Public Health Case Report, Release 2: the Electronic Initial Case Report (eICR), Release 1, STU Release 1.1 - US Realm

      Document Description

      extended per TSC Tracker 12574, extension TSC GF 15952, JIRA TSC-29, TSC-123

      Existing Wording

      This comment has been entered in a STU comment for STU Release 2.0 - see http://www.hl7.org/dstucomments/showdetail_comment.cfm?commentid=1990 HL7 CDA® R2 Implementation Guide:Public Health Case Report – the Electronic Initial Case Report (eICR) Release 1, STU Release 2.0- US Realm February 2020 1.1.3.3 documentationOf 10. MAY contain zero or one [0..1] documentationOf (CONF:4411-396). DocumentationOf is optional. You can specify a code for automated or can specify code for manual. What should happen if a code is not specified?

      Attachments

        Activity

          People

            Unassigned Unassigned
            emmanurse Emma Jones
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: