XMLWordPrintableJSON

Details

    • Icon: Change Request Change Request
    • Resolution: Persuasive
    • Icon: Medium Medium
    • Public Health Case Report - Electronic Initial Case Report (eICR) (CDA)
    • Public Health
    • TBD
    • Hide
      7/27/2017 ERRATA TYPE: Misleading Schematron error message ARTIFACTS AFFECTED: Schematron Will change the error if the Manual template is included but documentationOf is not included, to: "If the 'Initial Case Report Manual Initiation Reason' template is present then this must be a manually initiated eICR and documentationOf/serviceEvent must be present with code PHC1464: 'Manually Initiated eICR'"

      Show
      7/27/2017 ERRATA TYPE: Misleading Schematron error message ARTIFACTS AFFECTED: Schematron Will change the error if the Manual template is included but documentationOf is not included, to: "If the 'Initial Case Report Manual Initiation Reason' template is present then this must be a manually initiated eICR and documentationOf/serviceEvent must be present with code PHC1464: 'Manually Initiated eICR'"

    Description

      Specification - Extended

      HL7 CDA® R2 Implementation Guide: Public Health Case Report, Release 2: the Electronic Initial Case Report (eICR), Release 1, STU Release 1.1 - US Realm

      Document Description

      extended per TSC Tracker 12574, extension TSC GF 15952, JIRA TSC-29, TSC-123

      Existing Wording

      The schematron generated from Trifolia on 12/21/2016 doesn't check for the manual trigger template (2.16.840.1.113883.10.20.15.2.3.5) unless there is a documentation/serviceEvent in the header. documentationOf is listed as MAY in the specification, with no conditional requirements. You get this error if the manual template is included but documentationOf is not * An automatcially initiated eICR must contain at least one of Initial Case Report Trigger Code Lab Test Order, Initial Case Report Trigger Code Problem Observation, or Initial Case Report Trigger Code Result Observation. If documentationOf is included but the manual template is not, this error occurs * A manually initiation eICR must contain at least one Initial Case Report Manual Initiation Reason Observation.

      Proposed Wording

      Update the schematron to allow the below error to check for all four templates, and remove reliance on the documentationOf element. * An automatcially initiated eICR must contain at least one of Initial Case Report Trigger Code Lab Test Order, Initial Case Report Trigger Code Problem Observation, or Initial Case Report Trigger Code Result Observation.

      Attachments

        Activity

          People

            Unassigned Unassigned
            john_stamm John Stamm
            Watchers:
            0 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: