Specification - Extended HL7 CDA® R2 Implementation Guide: Public Health Case Report, Release 2: the Electronic Initial Case Report (eICR), Release 1, STU Release 1.1 - US Realm
Document Description extended per TSC Tracker 12574, extension TSC GF 15952, JIRA TSC-29, TSC-123
Existing WordingThe US Realm Address in the specification does not match the same template as it is used within other documents. Template 2.16.840.1.113883.10.20.22.5.2 (open) lists streetAddressLine as 1..1 SHALL. The definition of this template outside of this document allows 1..4 street address lines. The schematron generated from Trifolia on 12/21/2016 also enforces this extra requirement, causing this error when multiple streetAddressLines are included. SHALL contain exactly one [1..1] streetAddressLine (CONF:81-7291). (count(cda:streetAddressLine)=1) Consolidation documents for reference: http://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=5&cad=rja&uact=8&ved=0ahUKEwjui4-bqP7SAhWq5IMKHWo-AnwQFggxMAQ&url=http%3A%2F%2Fwiki.siframework.org%2Ffile%2Fview%2FConsolidation_V2_2013-07-22.docx&usg=AFQjCNE-JJD7H_9VEoX14gzeVo6gTurjAA&sig2=ICliCFp4rX4I51InD3G_-A
Proposed WordingUpdate the use of the US Realm Address template (2.16.840.1.113883.10.20.22.5.2) to have streetAddressLine as 1..4 SHALL. Update the schematron to enforce 1..4 SHALL instead of 1..1 SHALL.